VKING 6550C Xray inspection system increases operator's abilities to identify potential threats. The device can scan briefcases and carry on baggage as well as small cargo parcels. VKING 6500C is equipped with a superior image algorithm that can provide clear scanning images, which allow operators to identify possible threat items visually. VIKING 6550C is ergonomically designed and modern, which could assist operators in identifying suspicious items quickly and accurately. VKING 6550C Xray inspection system increases operator's abilities to identify potential threats. The device can scan briefcases and carry on baggage as well as small cargo parcels. VKING6550C is equipped with a superior image algorithm that can provide clear scanning images, which allow operators to identify possible threat items visually. VKING 6550C is ergonomically designed and modern, which could assist operators in identifying suspicious items quickly and accurately.
Availability: | |
---|---|
Quantity: | |
6550C
VIKING
202303061940
Tunnel size: | 655 * 505 mm (width * height) |
Conveyor speed: | 0.22 m/s |
Conveyor load: | 120 Kg (uniform load) |
Wear: | > 34 mm steel |
Line resolution: | > 38 AWG |
Spatial resolution: | horizontal / vertical Φ 1.0mm |
Control interface: | analog interface |
Tube voltage: | 140 ~ 160 KV (adjustable) |
Tube current: | 0.6 ~ 1.2 mA (adjustable) |
Cooling method: | sealed oil cooling, industrial fan cooling |
Work cycle: | 100%, no need to warm up |
Protection function: | over voltage, over current, over temperature protection |
Leakage rate: | < 0.5μGy / h (5cm from the outer shell) |
Single dose: | < 5.0μGy |
Safety: | Safety for film, chip, and electronics |
Radiation protection: | The channel inlet and outlet adopts 0.5mmPb double-layer environmental protection lead curtain protection, and the main body adopts 2 ~ 6mm lead plate protection to ensure that the peripheral radiation of the equipment meets national safety standards. |
Please check the actual radiation parameter records
Tunnel size: | 655 * 505 mm (width * height) |
Conveyor speed: | 0.22 m/s |
Conveyor load: | 120 Kg (uniform load) |
Wear: | > 34 mm steel |
Line resolution: | > 38 AWG |
Spatial resolution: | horizontal / vertical Φ 1.0mm |
Control interface: | analog interface |
Tube voltage: | 140 ~ 160 KV (adjustable) |
Tube current: | 0.6 ~ 1.2 mA (adjustable) |
Cooling method: | sealed oil cooling, industrial fan cooling |
Work cycle: | 100%, no need to warm up |
Protection function: | over voltage, over current, over temperature protection |
Leakage rate: | < 0.5μGy / h (5cm from the outer shell) |
Single dose: | < 5.0μGy |
Safety: | Safety for film, chip, and electronics |
Radiation protection: | The channel inlet and outlet adopts 0.5mmPb double-layer environmental protection lead curtain protection, and the main body adopts 2 ~ 6mm lead plate protection to ensure that the peripheral radiation of the equipment meets national safety standards. |
Please check the actual radiation parameter records