Views: 0 Author: Site Editor Publish Time: 2021-12-24 Origin: Site
This document defines the technical specifications and methods & procedures involved to test these features of Luggage Baggage X-Ray scanner 100100. The additional documents attached with this are:
1. Brochure / Technical data sheet
2. User manual containing operating and maintenance instructions/Procedures
S.NO | PRODUCT | CLIENT’S REQUIREMENT | TEST TYPE | PROCEDURE | VERIFIED | |
1 | Tunnel Dimension | 1m(W) x 1m(H0 Approx | Verify Physically | Measure through measuring tape or a baggage of this dimension should be passed through the machine | ||
2 | Conveyor Speed | 0.2m/s | Verify Physically | Make a marker on the middle of the belt ,then use the stopwatch test the minute distance then calculate the Second length | ||
3 | Conveyor Height | 300 mm | Verify Physically | Through measuring tape | ||
4 | Max Load | 200 Kg(evenly Distributed | Verify Physically | Put the load equivalent to 200 kg and let it pass through the machine | ||
5 | Resolution | 38 AWG/40 AWG | Verify Physically | You can cut one of the wire to check this | ||
6 | Steel Penetration | 30/38 mm | For Testing we require CTP/Test Procedure by Astrophysics and explanation | Use an organic things put into a 30mm plate then screen it, try to see if can screen the organic product in orange color | ||
7 | X-ray leakages | Less than 1µ Gy/hr (at a distance of 5cm from the housing), complying with all published international standards | For Testing we require CTP/Test Procedure by Astrophysics and explanation | Use a length 300mm,width300mm,height 75mm board to through the x ray machine ,Then watch the screen | X ray leakage detector | |
8 | Dose per inspection | Less than 1 µ Sv | Physically by functioning machine | X ray leakage detector | ||
9 | Film Safety | Guaranteed for high speed film up to ASA/ISP 1600 | Use the ISO 1600 Film through | |||
X RAY GENERATOR | ||||||
S.NO | PRODUCT | CLIENT’S REQUIREMENT | TEST TYPE | PROCEDURE | VERIFIED | |
1 | Anode Voltage | 160 K.v. | Electrical test method and Procedure. | 160 kV Operating at 150kV | It is inside the x ray generator | |
2 | Anode Current | 1ma | Electrical test method and Procedure. | Use Power meter | ||
3 | Cooling | Sealed oil bath | Test Method and Procedure. | Sealed Di- Electric Oil Bath with Forced Air | This device is inside the x ray source | |
4 | Duty Cycle | 100% | Test Method and Procedure. | Rated for 100% Duty Cycle | Procedure? | |
IMAGE ACQUISITION SYSTEM | ||||||
S.NO | PRODUCT | CLIENT’S REQUIREMENT | TEST TYPE | PROCEDURE | VERIFIED | |
1 | X Ray Converter | L Shaped detector Line | Physical and Functional | Physically by functioning machine | As show on the picture the part between the x ray source and x ray generator is the X ray converter | |
2 | Image Processing | 24 bits | Physical and Functional | Physically by functioning machine | ||
3 | Image Storage Capacity | Up to 50,000 images | Physical and Functional | Physically by functioning machine | ||
4 | Image Display | Color, Black& White, Multi energy, Multi absorptivity, inorganic stripping, Super enhancement, negative, high/low penetration | Physical and Functional | Observe the output | ||
5 | Region of interest(ROI) and Zoom | Selectable image, zoom regions,-1-32 times continuous enlargement, 1-3 times local enlargement | Physical and Functional | Physically by functioning machine | ||
6 | Image Recall | Preceding image recallable | Physical and Functional | Physically by functioning machine | ||
7 | Display Monitor | 17” high resolution LCD | Physical and Functional | Physically by functioning machine | ||
ADDITIONAL FUNCTIONS | ||||||
S.NO | PRODUCT | CLIENT’S REQUIREMENT | TEST TYPE | PROCEDURE | VERIFIED | |
1 | Standard Functions | System menu, power on self test, dates/time display, luggage counter, certified number of operators, mains record. System On/Ray on timer, operating mode display, image storage | Physical and Functional | Physically by functioning machine | Luggage counter?Yes Have this function ,please reference the picture enclosed that I mark ed red on The screen | |
2 | Optional | Explosives/Drugs Detection, Sound Alarm, Light alarm, image pic up system(CIS) | Physical and Functional | Physically by functioning machine | Can it be installed now, if yes what is the cost? | |
INSTALLATION DATA | ||||||
S.NO | PRODUCT | CLIENT’S REQUIREMENT | TEST TYPE | PROCEDURE | VERIFIED | |
1 | Storage Temperature/Humidity | -40 ° C to + 60 ° C 5% ~95%(Non Condensing) | Non-functional | -40 ° C to + 60 ° C 5% ~95% | ||
2 | Operating temperature/Humidity | 0 ° to + 40 ° 5% ~95%(Non Condensing) | Functional | 0 ° to + 40 ° 5% ~95% | ||
3 | Power supply | 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz) | Functional | 110-240 VAC(+10% to 15% and 50 Hz/60 Hz (+/- 3 Hz) | ||
4 | Power Consumption | 1.0 KVA | Functional | 1.0 KVA |
S.No | TEST | CLIENT’S REQUIREMENT | PROCEDURE | SPECIFIED | VERIFIED |
1 | Processor | Physical and Functional | Intel Core E3400 Duo, 2.6Ghz, 1 MHzL2 FSB800mHZ | ||
2 | Memory | Physical and Functional | 2 GB Kingston DDR3 1333MHZ 240pin | ||
3 | Storage | Physical and Functional | 500GB sea-gate HDD ST3500418AS | ||
4 | Video Card | Physical and Functional | Intel G41 ATX board | ||
5 | Platform | Physical and Functional | Windows XP Pro | ||
6 | Backup | Physical and Functional | No | ||
7 | Display Type | Dual 17” LCD Color Monitor | |||
8 | Display Resolution | Physical and Functional | 1280 x 1024; 24 Bit/pixel Color |
content is empty!